IVD™ 2, QED™, and ISORAD™ are easy-to-use solutions for monitoring patient dose radiation in real-time.
Uncomplicated In-Vivo Monitoring
Wired or wireless versions of this device are simple to install, easy to use, and feature automatic patient temperature compensation. Use it with a control module or PC software.
Detector Options
Choose from QED or ISORAD Detectors.
QED Detectors
For easy placement dose monitoring, QED detectors offer:
- Flat design for easy placement on patient
- 3 Photon Energy Ranges, 1 Electron Range, and Skin
- Accurate and stable SunPoint® Diode Detector
- Active dimension of 0.8 x 0.8 mm
- 3m/1.5m cable lengths available
ISORAD Detectors
For angular independent dose monitoring, ISORAD detectors offer:
- Cylindrical design for isotropic response
- Accurate and stable SunPoint Diode Detector
- Active dimension of 1.4 mm in diameter
- 3m/1.5m cable lengths available
IVD2 Device
Wired option includes four channels, expandable to 52 channels, and standard control module with PC software
rf-IVD 2 Device
Wireless option keeps cables off the treatment room floor
Control Module
Control module mounts to the wall, and removes the need for software
PC Software
Software includes Microsoft SQL patient database, automatic correction factors, Record and Verify interface, as well as patient data encryption, login monitoring, event tracking, and audit control.
Add these simple tools to your clinical workflows.
Resources
Downloads
Specifications
Channels |
Standard (rf-IVD 2/IVD 2): 8/4 |
Repeatability |
± 0.2% or ± 0.1cGy |
Polarity |
Bipolar (negative or positive polarity detectors) |
Leakage |
Automatic compensation |
Calibration |
User calibrated |
Warm-up time (sec) |
< 30 |
Wireless frequency (MHz) |
USA: 916.5; EU: 433.92 |
Power |
Rechargeable NiMH battery (12 hr) Power supply |
Dimension L/W/H (cm) |
7.0 x 12.0 x 3.0 |
Weight (kg) |
0.34 |
MoreLess |
Display Range |
0 to 99.999Gy; 0 to 9999.9cGy; 0 to 9999.9Rad |
Power |
LCD, 2 Line, 16 characters/line Medical power supply operating on 100-240 VAC, 47-63Hz mains, providing 18 VDC output |
Dimension L/W/H (cm) |
7.0 x 12.0 x 3.0 |
Weight (kg) |
0.78 |
Control module |
Standard |
PC Software |
Standard |
Number of pods |
rf-IVD 2: two; IVD 2: one (four channels) |
Wall-mounted charging bracket |
Standard |
Voltage |
1-4 MV |
6-12 MV |
15-25 MV |
Buildup material |
Brass |
Molybolenum |
Tungsten |
Buildup (g/cm2) |
1.0 |
1.1 |
1.8 |
Energy used for |
Co-60 |
6 MV |
18 MV |
Detector area (mm2) |
1.5 |
1.5 |
1.5 |
Active dimension (mm) |
1.4 diameter |
1.4 diameter |
1.4 diameter |
Dose rate dependence |
± 1%, 75 - 250cm SSD |
± 1%, 75 - 250cm SSD |
± 1%, 75 - 250cm SSD |
Detector sensitivity (nC/Gy) |
27.0 |
27.0 |
27.0 |
Detector stability |
0.5%/kGy at 6MV |
0.5%/kGy at 6MV |
0.5%/kGy at 6MV |
Color |
Blue |
Yellow |
Red |
Negative output P/N |
1162000-2 |
1163000-2 |
1164000-2 |
Positive output P/N |
1162000-3 |
1163000-3 |
1164000-3 |
MoreLess |
Voltage range |
Electron |
Skin |
Buildup material |
Acrylic |
None |
Buildup (g/cm2) |
0.3 |
0.1 |
Energy used for directional response |
6 MeV |
Co-60 |
Detector area (mm2 |
0.64 |
0.64 |
Active dimension (mm) |
0.8 x 0.8 |
0.8 x 0.8 |
Dose rate dependence |
± 1%, 75 - 250cm SSD |
± 1%, 75 - 250cm SSD |
Detector sensitivity (nC/Gy) |
32.0 |
32.0 |
Detector stability |
0.5%/kGy at 6MV |
0.5%/kGy at 6MV |
Color |
Grey |
Black |
Negative output P/N |
1112000-2 |
1113000-2 |
Positive output P/N |
1112000-3 |
1113000-3 |
MoreLess |
Voltage range |
1-4 MV |
6-12 MV |
15-25 MV |
Buildup material |
Aluminum |
Brass |
Brass |
Buildup (g/cm2) |
0.9 |
1.5 |
2.5 |
Energy used for directional response |
Co-60 |
6 MV |
18 MV |
Detector area (mm2) |
0.64 |
0.64 |
0.64 |
Active dimension (mm) |
0.8 x 0.8 |
0.8 x 0.8 |
0.8 x 0.8 |
Dose rate dependence |
± 1%, 75 - 250cm SSD |
± 1%, 75 - 250cm SSD |
± 1%, 75 - 250cm SSD |
Detector sensitivity (nC/Gy) |
32.0 |
32.0 |
32.0 |
Detector stability |
0.5%/kGy at 6MV |
0.5%/kGy at 6MV |
0.5%/kGy at 6MV |
Color |
Blue |
Yellow |
Red |
Negative output P/N |
1114000-2 |
1115000-2 |
1116000-2 |
Positive output P/N |
1114000-3 |
1115000-3 |
1116000-3 |
MoreLess |