The IMRT/ VMAT Phantoms are designed to address the complex issues surrounding commissioning and comparison of treatment planning systems and complete system QA from CT imaging to dose verification


IMRT Verification and End-to-End Solution

The IMRT phantoms are manufactured from tissue equivalent materials that mimic within 1% from 50 keV to 15 MeV for accurate simulation during all necessary steps of IMRT verification.


IMRT Thorax Phantom

  • Verify heterogeneity corrections
  • Correlate CTU to electron density
  • Check dose distributions in sensitive areas
  • Check depth doses and absolute dose
  • 2D and 3D isodose
  • Calibrate film with ion chamber and other detectors
  • Accommodate additional, optional breast attachments

IMRT Head & Torso Freepoint Phantom

With this phantom, choose any point dose location within a circular area with diameter of 11.2 cm by simply adjusting the two rotating cylinders

  • Ion chambers, TLD, MOSFET and Diodes easily positioned using interchangeable rods
  • Use radiographic film dosimetry
  • CT film markers ensure accurate film to plan registration
  • Surfaces are etched with indices for precise alignment
  • Configure with or without heterogeneities
  • Calibrate film with ion chamber and other detectors
  • Accommodate additional, optional breast attachments

IMRT Pelvic 3D Phantom

  • Verify heterogeneity corrections
  • Correlate CTU to electron density
  • Check dose distributions in sensitive areas
  • Check depth doses and absolute dose
  • 2D and 3D isodose
  • Calibrate film with ion chamber and other detectors

Phantom Patient for VMAT & IMRT

  • Suitable for use with various commercially available fixation devices
  • Enables dose measurements in large regions of the head and neck through the use of radiographic film
  • Allows dose measurements with ion chambers
  • Performs Electron Density calibration in shoulders

Optimize precision with our IMRT/VMAT phantoms


The interchangeable rod design allows the phantom to accommodate many dose measurement devices such as ion chambers, TLD, diodes and MOSFET’s in the same location within the phantom. Phantom cross sections accommodate GafChromic® film.


IMRT Thorax Phantom

IMRT Head & Torso Freepoint Phantom

IMRT Pelvic 3D Phantom



Specifications

IMRT Thorax Phantom

Dimensions

43.2 cm x 38.1 cm x 22.9 cm

(17 ”x 15” x 9”)

Weight

30 lbs (11.2 kg)

Materials

Phantom Body: Tissue Equivalent Epoxy Materials

Inserts: Tissue Equivalent Materials (epoxy resin-based)

IMRT Head & Torso Freepoint Phantom

Dimensions

43.2 cm x 39.4 cm x 25.4 cm

(17 ”x 15” x 9”)

Weight

47 lbs (17.5 kg)

Materials

Phantom Body: Tissue Equivalent Epoxy Materials

Inserts: Tissue Equivalent Materials (epoxy resin-based)

IMRT Pelvic 3D Phantom

Dimensions

35.6 cm x 38.1 cm x 22.9 cm

(14" x 15" x 9")

Weight

10.5 kg (28 lb)

Materials

Phantom Body: Tissue Equivalent Epoxy Materials

Inserts: Tissue Equivalent Materials (epoxy resin-based)

Phantom Patient for VMAT & IMRT

Dimensions

36 cm (W) x 36 cm (L) x 22cm (H)

Weight

10.2 kg without rods

Materials

Proprietary epoxy resins.