EDGE Detector™ characterizes penumbra more precisely and with less averaging than ion chambers, making it the preferred detector for small field beam modeling and QA.
Waterproof and highly accurate, it works with all common water phantoms for SRS and IMRT beam modeling and TPS commissioning.
Well-Suited for Small Fields
EDGE Detector is comprised of a SunPoint® Diode Detector that is 842 times smaller, and has 100 times more signal, than micro ionization chambers. Its small size makes it ideal for accurate penumbra characterization and steep gradients for fields ≤10 cm.
Maintain Compliance
EDGE Detector supports compliance with TRS483 and precision dosimetry.
"The practical methods described can be used for commissioning an SRS system with small cones. New correction factors significantly improve agreement between different detectors."
Measurement of Output and Percent Depth Dose (PDD) for Small Stereotactic Radiosurgery (SRS) Cones Using Semiconductor and Microdiamond Detectors
Add this detector to your small field toolkit.
Resources
Publications
- Impact of detector selections on inter-institutional variability of flattening filter-free beam data for TrueBeam™ linear accelerators
- The clinical impact of detector choice for beam scanning
- Correction factor measurements for multiple detectors used in small field dosimetry on the Varian Edge radiosurgery system
- Measurement of Output and Percent Depth Dose (PDD) for Small Stereotactic Radiosurgery (SRS) Cones Using Semiconductor and Microdiamond Detectors
- Stereotactic Detector Comparisons for Small Field Relative Dosimetry
- End-To-End Testing of Linac-Based SRS Using Radiochromic Film & CIRS STEEV Phantom
- Variation of Detector Specific Output Correction Factors for Small Fields From Different Linacs/collimation Systems
- Intercomparison of Stereotactic Scanning Diodes for Small Field Dosimetry
- Experimental Comparison of Seven Commercial Dosimetry Diodes for Measurement of Stereotactic Radiosurgery Cone Factor
- MoreLess
Specifications
Active Detection Area (mm) |
0.8 x 0.8 |
Diode Die Location (mm) |
2.7 from side; location is indicated by cross hairs on top of the housing |
Water Depth Equivalent (mm) |
0.5 |
Housing Wall Thickness (mm) |
0.13 brass |
External Dimensions (mm) |
3.8 x 5.5 x 38 |
Nominal Sensitivity (nC/Gy) |
32.0 |
Impedance (Mohm) |
>200 at 10 mV reverse bias |
Output Polarity |
Negative |
Cable |
3.4 mm dia. x 1.8 m long, triax |
Cable Connector |
BNC or TNC triax, or adapters upon request |
MoreLess |